id severity disposition title
CR-01 critical open Human review is checked against a different file from the selected receipt
id severity disposition title
CR-02 critical open Original applicability never binds the executed executable or preservation inventories
id severity disposition title
CR-03 critical open Fresh-copy continuity accepts a hash that identifies no artifact
id severity disposition title
WR-01 warning open Checkpoint assembly bypasses the capability ledger projection
id severity disposition title
WR-02 warning open An interrupted Windows collector cannot be finalized through the documented recovery command
5 5 2026-11-13T21:58:50.502559+00:00

Phase 01: Code Review Disposition

Finding Severity Disposition Source
CR-01 critical open Reproduced; fix in progress
CR-02 critical open Reproduced; fix in progress
CR-03 critical open Reproduced; fix in progress
WR-01 warning open Reproduced; fix in progress
WR-02 warning open Reproduced; fix in progress